Browse all practice questions for the ASSE Backflow Recertification Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

ASSE Backflow Recertification Practice Exam course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What must be done with the original signed and tested date test report?
  • What is the minimum hose diameter required for a pressure gauge used in backflow testing?
  • High velocities in undersized water piping may cause what issue?
  • Test cock #1 on a 2" and smaller pressure vacuum breaker is located between the check valve and the:
  • What is the primary purpose of pressure relief valves in backflow prevention assemblies?
  • What action must be taken if a backflow test indicates the assembly is failing?
  • For what purpose are thermal expansion tanks used?
  • Which backflow prevention device is specifically designed to protect against backflow caused by back pressure?
  • Which of the following pieces of information is NOT required on a Backflow report?
  • Which of the following can lead to backpressure conditions?
  • What is the minimum protection required for containment protection in a non-health hazard situation?
  • An air gap, affected by two interesting walls, must be how many times the effective opening of the potable water outlet?
  • If the check valve springs are interchangeable on a double check assembly, what impact does this have?
  • What is the approximate gauge pressure (PSIG) equivalent to an absolute pressure of 25 psia?
  • What is the primary purpose of a backflow preventer?
  • What is the function of test cocks in backflow prevention assemblies?
  • What is one of the key features of a double check valve assembly?
  • Which equipment is specifically used for testing a pressure vacuum breaker?
  • What should be done if the differential pressure relief valve does not open as required?
  • When testing a spill resistant vacuum breaker, to which test cock should you attach the high hose?
  • What should be regularly tested to ensure the effectiveness of backflow prevention?
  • What typically causes intermittent or spitting discharges from the relief valve during a no flow condition?
  • Before which point must the air inlet of a pressure vacuum breaker open according to pressure gauges?
  • Which device is commonly used to control thermal expansion problems?
  • What is the required backflow protection for a fire sprinkler system containing chemicals?
  • How is an air gap separation measured?
  • What component of a backflow prevention device typically serves a relief function in a RPZ?
  • Which testing method is used to ensure the functionality of a RPZ?
  • If the relief valve of a Reduced Pressure Zone (RPZ) assembly fails to open during a field test, what is the probable cause?
  • What information is required to properly identify the backflow assembly to be tested?
  • The function of a double check valve is primarily to prevent what?
  • Which part is not required for an atmospheric type vacuum breaker?
  • Which of the following materials is not considered a high hazard?
  • What conditions might necessitate the installation of a backflow preventer?
  • A double check backflow prevention assembly contains which component?
  • Which type of backflow prevention device is required for a chemically treated boiler system on the potable water system?
  • Where is test cock number one located on an approved double check valve assembly?
  • How many standard test cocks are present in a typical double check valve assembly?
  • A pressure of 75 psi is equivalent to how many feet of head pressure?
  • What could a significant risk to a potable water supply system from improper backflow prevention installations lead to?
  • A leaking check valve may be caused by which of the following?
  • What would a gauge installed at the bottom of a 10-foot deep open water tank indicate in terms of pressure?
  • When testing a double check valve assembly, which shutoff valve should be closed first?
  • What is a common sign of malfunction in a backflow prevention assembly?
  • True or False: Contaminant devices should be installed at the service connection in high hazard facilities.
  • The application of a pressure vacuum breaker is for:
  • What is the standard pressure exerted at one foot of water column?
  • What is the primary purpose of a pressure vacuum breaker assembly?
  • Which of the following is NOT necessary for testing a double check valve?
  • Which of the following is not considered a source of backpressure?
  • What is the main purpose of testing Backflow prevention devices?
  • How much pressure is exerted at the base of a column of water that is two feet tall?
  • How many times the effective opening of the water supply outlet piping must the vertical distance of an air gap separation be?
  • What does constant discharge from the relief valve of a Reduced Pressure Principle assembly usually indicate?
  • Before attaching a test kit to a Reduced Pressure Zone (RPZ), why does the tester open test cock 4 and allow it to trickle?
  • What safety measure should be followed during Backflow testing?
  • What type of protection is required for a closed loop heating system containing chemicals?
  • Which of the following is NOT a reason for installing test cocks?
  • What is defined as the force exerted by a fluid at rest?
  • What type of backflow prevention is required for a closed-loop system that contains antifreeze?
  • What is a key factor in determining the appropriate type of backflow prevention device to install?
  • A Backflow test gauge (differential pressure gauge) should be stored with all needles:
  • What is an example of a device that provides backsiphonage protection?
  • A check valve in an approved backflow assembly must be tight when?
  • Which component is measured during a directional flow test on an RPZ assembly?
  • What is required protection for a closed loop system containing glycol?
  • Which of the following is a key maintenance practice for backflow prevention devices?
  • Which type of backflow assembly is primarily used in commercial applications?
  • Which test cocks must be open to test the differential pressure drop across check valve number one on a double check?
  • What type of hazard does RPZ protect against?
  • On an approved pressure vacuum breaker assembly, where are the shut off valves located?
  • What is the main purpose of a vacuum breaker?
  • What type of backflow protection is required for a chemically charged solar heating system with an expansion tank?
  • What does RPZ stand for in the context of backflow prevention?
  • What is defined as dynamic pressure in a fluid system?
  • Which instrument can be used to test a double check Backflow prevention device?
  • What is the maximum allowable pressure loss during rated flow across a double check?
  • During a field test, where is the vent screw located in relation to a Pressure Vacuum Breaker Assembly check valve?
  • Which of the following systems typically requires a backflow prevention device?
  • How many test cocks are required on a 2 inch and smaller pressure vacuum breaker?
  • A primary cause of reversal flow of water in a piping system is:
  • What is the minimum reading required when performing a directional flow test on the #2 check valve of a RPZ?
  • What is the primary consideration in determining what type of backflow prevention to install?
  • Are atmospheric type vacuum breakers and pressure vacuum breaker assemblies effective for protection against backpressure?
  • How many feet of water can a perfect vacuum at sea level theoretically raise in a pipe?
  • What is the minimum type of containment protection required for a non-health hazard, non-chemical sprinkler?
  • What is the critical final step in testing a backflow prevention assembly?
  • What is the initial step to take when installing a backflow prevention device?
  • A double check valve protects the potable water supply from what type of hazard?
  • A system that includes a chemical injector must have what type of protection for the potable system?
  • What does constant discharge from the relief valve of a reduced pressure principle assembly usually indicate?
  • What is one common reason for backflow to occur in a water system?
  • What does "Containment" protection imply in a backflow prevention context?
  • When is it necessary to utilize a reduced pressure zone (RPZ) assembly?
  • When performing a test on a RPZ, the #2 test cock should be:
  • Continuous leakage from test cock #2 during a test of a pressure vacuum breaker is likely due to what issue?
  • Which of the following is not a method used for Backflow prevention?
  • What is the suggested minimum vertical distance between the relief valve discharge port of a RPZ and the surrounding floor or grade?
  • What is an acceptable means of backflow prevention?
  • The differential pressure relief valve on a Reduced Pressure Zone (RPZ) assembly must open before the differential pressure across the inlet drops below what value?
  • What is the role of a test cock in a backflow prevention assembly?
  • What type of environment would require a high hazard backflow prevention device?
  • A double check valve assembly consists of how many check valves and shutoff valves?
  • The term "approved reduced pressure principle assembly" applies to what configuration?
  • In facilities using a contaminated auxiliary water supply for fire protection, what is required for the potable water service connection?
  • What is the most desirable location to install a Backflow?
  • What type of backflow device is required for the main water supply to a waste management plant?
  • What is a probable cause for a relief valve failing to open during a field test of an RPZ?
  • What is the primary operational concern of a backflow prevention device?
  • The portable water supply to a urinal equipped with a flushometer valve is protected by which type of backflow device?
  • What safety feature is crucial in preventing backflow in systems with potentially hazardous potable water?
  • What causes a pressure vacuum breaker assembly to chatter during flow conditions?
  • What is the purpose of the air gap in backflow prevention?
  • What feature primarily distinguishes a reduced pressure backflow preventer from other devices?
  • What is an example of a potential backpressure plumbing connection?
  • What is the primary role of a check valve in backflow prevention?
  • Which component is present in a hose connection to provide high hazard protection?
  • What absolute pressure could cause backsiphonage to occur in a hydraulic system at sea level?
  • What is the critical component of an atmospheric type vacuum breaker that is subject to failure?
  • A dual check valve is used to protect against which hazards?
  • An atmospheric type vacuum breaker is primarily installed to protect against what?
  • What type of pressure is indicated during a flow test on a check valve?
  • What is the most common Backflow prevention device installed at a residential meter?
  • What is the intended use of a laboratory faucet backflow device?
  • The following statement is true regarding atmospheric type vacuum breakers:
  • Which of the following will not create a closed loop piping system?
  • Before installing a reduced pressure zone (RPZ) device, what special consideration should be noted?
  • What is characterized as backpressure?
  • What does the term "backsiphonage" refer to?
  • What is the primary purpose of a backflow prevention device?
  • What type of pressure is indicated by a pressure gauge at a specific depth in a water column?
  • What is the required backflow protection for a solar heating system that is chemically charged and includes an expansion tank?
  • What is the required number of test cocks on a small (3/4"-2") pressure vacuum breaker?
  • A double check valve assembly that shows equal pressure between the check's inlet and outlet indicates what condition?
  • A pressure gauge reading of 50 psi can indicate a column of water is approximately how many feet high?
  • True or False: Supply pressure fluctuations may cause the relief valve of an RPZ to open on occasion.
  • Where is an atmospheric type vacuum breaker most likely installed?
  • An occasional discharge from the relief valve of a RPZ indicates what?
  • What is the purpose of testing backflows annually?
  • In relation to backflow prevention, what does RPZ stand for?
  • What is the purpose of a reduction pressure zone (RPZ) assembly?
  • In the context of backflow prevention, what defines a check valve's function?
  • What are the minimum scale increments allowed on a differential pressure gauge used for testing backflow assemblies?
  • What determines the degree of hazard for a non-potable water source?
  • What does the acronym RPZ stand for in backflow prevention?
  • True or False: The vent hose on a differential test kit is used to bypass the Backflow device so water service is uninterrupted during testing.
  • Which description best fits Dual Check Backflows (ASSE 1024)?
  • Which component is NOT part of a double check assembly?
  • Which device/assembly cannot sustain continuous pressure downstream?
  • The bypass line of a backflow must contain an approved assembly of equal what?
  • What is the required type of protection between a potable water system and a building sewer?
  • Why is an air gap important in backflow prevention?
  • Which condition could result in water contamination through cross connection?
  • One atmosphere of pressure is equivalent to how high of a column of water at sea level?
  • In order to maintain water service during Backflow testing, what must be ensured?
  • What term can also be used to describe sub-atmospheric pressure?
  • How often do USC, AWWA, and manufacturers recommend inspecting backflow prevention assemblies?
  • What does the spring in the relief valve assembly of an RPZ do?
  • What minimum markings are required on a backflow prevention assembly?
  • Which component is essential for testing backflow prevention devices and assemblies?
  • An increase of pressure in a closed system due to heat and expanding of water is known as:
  • Which of the following is NOT a reason for backflow prevention failure?
  • What risk arises when a hydronic system is directly connected to a domestic water system without proper backflow protection?
  • What component is crucial for the operation of a pressure vacuum breaker?
  • Which component helps to keep a check valve operational?
  • Which of the following is an advantage of using an air gap?
  • If the check valve springs are interchanged on a double check valve, how will the assembly be affected?
  • An indirect cross connection allows what type of backflow to occur?
  • Which valve must be closed when testing a Reduced Pressure Zone (RPZ) assembly?
  • The relief valve of an RPZ must open at what pressure?
  • An atmospheric pressure vacuum breaker shall not be subjected to water pressure for more than how many hours?
  • Why is proper installation of backflow prevention devices crucial?
  • What is the formula for calculating absolute pressure at sea level?
  • When testing a differential pressure gauge, where is water pressure bled through?
  • What is the correct procedure to begin testing a Reduced Pressure Zone (RPZ) device?
  • What is an essential function of a backflow preventer?
  • A pressure of 75 psi is equivalent to how many feet of water head?
  • A ___ would be least likely to require a RPZ to be installed as contaminant protection?
  • Which test is critical to ensuring that a backflow prevention assembly is operational?
  • When a facility requires continuous and uninterrupted water pressure, what is the recommended setup for Backflow assemblies?
  • Which type of protection is associated with air gap separation?
  • Where is the reduced pressure zone located in a reduced pressure principle backflow preventer device?
  • What should be done if a test cock is found to be plugged?
  • How high can atmospheric pressure at sea level support a column of water?
  • What indicates a failure in a check valve during testing?
  • Which factor can significantly affect the performance of a backflow prevention assembly?
  • What is the main purpose of a reduced pressure zone (RPZ) backflow preventer?
  • In a backflow prevention assembly, what does the term "test cock" refer to?
  • Can a double check backflow device be used on a system containing antifreeze?
  • What maintenance action is essential for ensuring the reliability of a backflow assembly?
  • In backflow prevention, what does "backsiphonage" refer to?
  • What classification would waste from a chemical plant typically fall into?
  • A differential pressure gauge is used to test which types of backflow assemblies?
  • Which test cock number should be opened to establish flow through a backflow preventer?